These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Improved preoperative evaluation of cerebral cavernomas by high-field, high-resolution susceptibility-weighted magnetic resonance imaging at 3 Tesla: comparison with standard (1.5 T) magnetic resonance imaging and correlation with histopathological findings--preliminary results.
    Author: Pinker K, Stavrou I, Szomolanyi P, Hoeftberger R, Weber M, Stadlbauer A, Noebauer-Huhmann IM, Knosp E, Trattnig S.
    Journal: Invest Radiol; 2007 Jun; 42(6):346-51. PubMed ID: 17507804.
    Abstract:
    OBJECTIVES: To compare high-field, high-resolution, susceptibility-weighted magnetic resonance imaging (3 Tesla [T] HR-SW-MRI) and standard (1.5 Tesla [T]) MRI for the detection of cerebral cavernomas. To evaluate the ability of 3 T HR-SW-MRI to visualize intralesional structures compared with standard (1.5 T) MRI, in correlation with histopathologic findings. MATERIALS AND METHODS: Seventeen patients with cerebral cavernomas underwent both standard (1.5 T) MRI (T1-SE, T2-TSE, T2*-GRE) and 3 T HR-SW-MRI (TR/TE 43.3/9.1 millisecond; 512 x 384 x 48 matrix; FOV 250 mm; SI 72 mm) at our institution. All MR images were evaluated by 3 radiologists in consensus for detectability, size (</>1 cm), and conspicuity (good, acceptable, poor) of the lesions at both field strengths, and for the presence of hypointense intralesional tubular structures. In 7 patients, MR findings were correlated with histopathologic findings. RESULTS: Both 3 T HR-SW-MRI and standard (1.5 T) MRI detected 22 lesions in 17 patients; 3 T HR-SW-MRI detected an additional 7 lesions in 6 patients. On average, 3 T HR-SW-MRI detected 1.706 +/- 0.92 (median = 1) lesions per patient, whereas standard (1.5 T) MRI detected 1.235 +/- 0.664 lesions per patient (P = 0.016). Lesion conspicuity was good in all 3 T HR-SW-MR images and good in 68.2% and acceptable in 31.8% of standard (1.5 T) MR images (P = 0.016). In 22 lesions detected at both field strengths, 3 T HR-SW-MRI demonstrated intralesional tubular structures in 72.7% and standard (1.5 T) MRI demonstrated these structures in 31.8% (P = 0.001). Intralesional tubular structure correlated to conglomerates of cavernous vessel, as verified by histopathology. CONCLUSION: Compared with standard (1.5 T) MRI, 3 T HR-SW-MRI allows superior detection and characterization of cerebral cavernomas. Despite increased susceptibility effects, ie, signal loss at higher magnetic field strengths, the visualization of intralesional tubular structures is feasible. This may be helpful in the diagnosis, presurgical planning, and noninvasive follow-up after gamma-knife radiosurgery.
    [Abstract] [Full Text] [Related] [New Search]