Search MEDLINE/PubMed
Title: Set-up of a passive Bonner sphere system for neutron spectrometry at mixed fields with predominant photon component based on activation detector. Author: Amgarou K, Lacoste V, Muller H, Fernández F. Journal: Radiat Prot Dosimetry; 2007; 126(1-4):337-41. PubMed ID: 17513860. Abstract: A passive Bonner sphere system (BSS), based on thermal neutron activation detectors, was developed to perform neutron spectrometry in pulsed and very intense (n-gamma) fields with predominant photon component, as those produced by high energy (>10 MV) medical linear electron accelerators. In this paper, a description of the new system is presented together with an experimental characterisation of a portable Sodium Iodide (NaI) detector and a fixed high-purity Germanium one, both used to measure the induced gamma-activity of the activated materials, respectively, in situ and in the laboratory. The choice of the activated materials is justified according to pre-established practical considerations and physical criteria. The response functions of the entire passive BSS were calculated using the MCNPX code. A preliminary experimental validation with a bare (252)Cf source is given as well.[Abstract] [Full Text] [Related] [New Search]