These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification. Observational study. Author: Vasavada V, Vasavada V, Raj SM, Vasavada AR. Journal: J Cataract Refract Surg; 2007 Jun; 33(6):1019-24. PubMed ID: 17531697. Abstract: PURPOSE: To evaluate the intraoperative performance and postoperative outcomes after microcoaxial phacoemulsification. SETTING: Iladevi Cataract & IOL Research Centre, Ahmedabad, India. METHODS: A prospective observational case series comprised 84 eyes with age-related uncomplicated cataract having microcoaxial phacoemulsification through a 2.2 mm clear corneal incision by a standard surgical technique. Phacoemulsification parameters (Infiniti Vision System, Alcon) were microburst width, 30 ms; preset power, 50%; vacuum, 650 mm Hg; aspiration flow rate, 25 cc/minute. A single-piece Alcon AcrySof intraocular lens was implanted with the C cartridge (Alcon) cartridge. The incision was measured at the end of surgery. Observations included surgical time (from commencement of sculpting to end of epinucleus removal), cumulative dissipated energy (CDE), wound burns, intraoperative complications, postoperative increase in mean central corneal thickness (CCT) at 1 day and 1 month, mean % decrease in endothelial cell density (ECD), absolute mean change in coefficient of variation (cv) 3 months, and uncorrected visual acuity (UCVA) at 1 day. Data were analyzed using a 1-sample t test with 95% confidence intervals (CIs). RESULTS: The mean follow up was 3 months +/- 0.3 (SD). The mean incision size at the end of surgery was 2.3 +/- .09 mm; mean surgical time, 4.5 +/- 1.5 minutes; and mean CDE, 2.3 +/- 2.2 seconds. No wound burns or other intraoperative complications occurred. The postoperative CCT increased by a mean of 16 microm at 1 day (95% CI, 8-25; P = .66;) and by a mean of 3.14 microm at 1 month (95% CI, 2.26-4.05; P = .92). The ECD decreased by a mean of 5.8% (95% CI, 6.8-3.5; P = .82) and the mean coefficient of variation, by 3.3 (95% CI, 4.5-2.0; P = .65). At 1 day, the UCVA was 20/20 in 29% of cases, 20/20 to 20/40 in 58%, and 20/40 to 20/50 in 12%. CONCLUSION: Microcoaxial phacoemulsification was safely and effectively performed, achieving consistent and satisfactory postoperative outcomes.[Abstract] [Full Text] [Related] [New Search]