  • Title: Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses: a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials.
    Author: Weissman NJ, Ellis SG, Grube E, Dawkins KD, Greenberg JD, Mann T, Cannon LA, Cambier PA, Fernandez S, Mintz GS, Mandinov L, Koglin J, Stone GW.
    Journal: Eur Heart J; 2007 Jul; 28(13):1574-82. PubMed ID: 17540849.
    Abstract:
    AIMS: The TAXUS Express stent has been shown to reduce angiographic restenosis, repeat revascularizations, and neointimal hyperplasia when compared with bare metal stent (BMS) control (TAXUS IV, V, and VI) in individual TAXUS trials. Since intravascular ultrasound (IVUS) methodology and core laboratory were consistent among all three TAXUS trials, an integrated analysis of 956 patients across all IVUS cohorts can be performed providing superior power. METHODS AND RESULTS: In the TAXUS randomized trials, patients received an Express BMS or paclitaxel-eluting TAXUS Express stent. Volumetric analysis was performed on a selected subgroup at implantation and 9 months. Compared with BMS control, TAXUS increased 9-month lumen volumes (144 +/- 79 vs. 179 +/- 95 mm(3); P < 0.0001) due to reduced neointimal volume (66 +/- 49 vs. 27 +/- 30 mm(3); P < 0.0001). This corresponded to a 61% decrease in net lumen volume obstruction (31 +/- 15 vs. 12 +/- 12 mm(3); P < 0.0001). Lumen loss was similar between groups for the proximal 5 mm outside the stent but was reduced in TAXUS at the distal edge (P = 0.0056). Neointimal hyperplasia was significantly reduced in the double-strut region of overlapping TAXUS vs. BMS control and in high-risk patients with diabetes, long lesions, multiple stents, and multiple overlapping stents. Late-acquired incomplete stent apposition (ISA) was more common with moderate-release TAXUS stents. Importantly, there were no major adverse cardiac events or stent thromboses in any late-acquired ISA patient through 2 years. Univariate and multivariable analyses revealed that longer lesion length and previous myocardial infarction are risk factors for late-acquired ISA. CONCLUSION: Integrated analysis of the TAXUS trials shows that the paclitaxel-eluting TAXUS Express stent effectively inhibits in-stent neointimal proliferation, even in high-risk and overlapping stent patients.
    [Abstract] [Full Text] [Related] [New Search]