These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma.
    Author: Kang W, Jeong JH, Ma E, Kwon KI.
    Journal: J Pharm Biomed Anal; 2007 Sep 03; 44(5):1178-82. PubMed ID: 17561362.
    Abstract:
    A simple and rapid quantification method was developed for determining menatetrenone and its epoxide metabolite in human plasma. After a simple protein precipitation with methanol, the analytes were chromatographed on a reversed-phase C(18) column and detected by LC/MS/MS with atmospheric pressure chemical ionization. The coefficient of variation of the assay precision was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of detection of menatetrenone and its epoxide was 0.5 and 0.2 ng/ml, respectively. This method was used to simultaneously measure the plasma concentration of menatetrenone and its epoxide metabolite from healthy subjects after a single 30 mg oral dose of menatetrenone.
    [Abstract] [Full Text] [Related] [New Search]