These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Long-term safety and functional outcome of combined pars plana vitrectomy and scleral-fixated sutured posterior chamber lens implantation.
    Author: Bading G, Hillenkamp J, Sachs HG, Gabel VP, Framme C.
    Journal: Am J Ophthalmol; 2007 Sep; 144(3):371-377. PubMed ID: 17624290.
    Abstract:
    PURPOSE: To investigate the complication profile and the long-term functional outcome of combined pars plana vitrectomy and scleral-fixated sutured posterior chamber lens (PC IOL) implantation. DESIGN: Retrospective, consecutive, interventional case series. METHODS: The records of 63 patients (mean age, 67.5 years) were reviewed retrospectively (follow-up, 12 to 132 months; mean, 43.5 months). The underlying ocular pathologic features; the intraoperative, early (within two weeks after surgery), and late complications (more than two weeks after surgery); final best-corrected visual acuity (BCVA); and the refractive outcome were recorded. RESULTS: Fifty-nine of 63 procedures (93.7%) were performed without complications. Intraoperative complications included vitreous hemorrhage (n = 2), a retinal tear (n = 1), and a rupture of the iris base (n = 1). Early complications included transient raise of intraocular pressure (IOP; n = 19), transient vitreous hemorrhage (n = 2), scleral tunnel insufficiency (n = 5), pupillary capture of intraocular lens [IOL] (n = 6), persistent vitreous (n = 3), and choroidal hemorrhage (n = 1). Late complications occurred in 12 patients: rhegmatogenous retinal detachment (n = 4), proliferative vitreoretinopathy retinal detachment secondary to the underlying ocular pathologic features (n = 2), choroidal hemorrhage (n = 1), macular pucker (n = 1), and IOL dislocation (n = 4), including two cases of suture break. Mean BCVA in logarithm of the minimum angle of resolution units improved significantly from 1.025 (standard deviation [SD], 0.654) to 0.766 (SD, 0.750; P = .03). Mean cylindric equivalent significantly changed from 0.92 diopters (D; SD, 1.075) to 1.76 D (SD, 1.344; P = .005). CONCLUSIONS: The surgical procedures were performed safely in approximately 94% of patients. Most postoperative complications were minor: significant ones occurred in approximately 20%, whereas suture breaks were observed rarely. The only moderate long-term functional improvement in this case series was mainly determined by the underlying ocular pathologic features.
    [Abstract] [Full Text] [Related] [New Search]