These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A new intra-arterial delivery platform for pro-arteriogenic compounds to stimulate collateral artery growth via transforming growth factor-beta1 release. Author: Grundmann S, van Royen N, Pasterkamp G, Gonzalez N, Tijsma EJ, Piek JJ, Hoefer IE. Journal: J Am Coll Cardiol; 2007 Jul 24; 50(4):351-8. PubMed ID: 17659203. Abstract: OBJECTIVES: The purpose of this study was to develop a cytokine-eluting stent to stimulate collateral artery growth (arteriogenesis) in the peripheral circulation of the rabbit via local transforming growth factor (TGF)-beta1 release. BACKGROUND: The stimulation of arteriogenesis with cytokines is a potential new treatment option for patients suffering from vascular occlusive diseases. However, the lack of a delivery platform for continuous intra-arterial application of pro-arteriogenic compounds has hampered the clinical implementation of this promising therapeutic strategy. METHODS: Different polymer coatings were tested regarding their suitability for cytokine release. Fifty-four rabbits underwent implantation of bare-metal stents (BMS), polymer-only coated stents (PDLLA), polymer-coated TGF-beta1-eluting stents (TGF) in the iliac artery, or bolus infusion of TGF-beta1 and subsequent femoral artery ligation. Collateral artery growth was assessed with fluorescent microspheres, angiography, and histological quantification of the proliferation marker Ki67. In-stent neointima formation was measured in histological sections of plastic-embedded stents. RESULTS: A TGF-beta1-loaded coating based on poly(D,L-lactide) released up to 2.4 microg active TGF-beta1 over a period of 24 h. Perfusion measurements revealed a significant increase in collateral conductance after TGF-beta1 stent implantation compared with the control groups ([ml/min/100 mm Hg] BMS: 47.8 +/- 2.5; PDLLA: 44.1 +/- 3.9; TGF: 91.3 +/- 32.6). Bolus infusion of TGF-beta1 had no effect. Collateral arteries showed a higher proliferation activity in the TGF-treated group. At 7 days, no significant difference in in-stent neointima formation was observed. CONCLUSIONS: We first describe the use of a cytokine-releasing stent to stimulate collateral artery growth. These results show that intra-arterial cytokine-releasing devices might serve as a novel platform for the delivery of compounds affecting biological processes downstream of the site of implantation.[Abstract] [Full Text] [Related] [New Search]