These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Leukocyte removability of a newly developed filter, RC-100, in rapid transfusion].
    Author: Shibata H, Kuro M, Takaki O, Uchida O, Kitaguchi K, Hayashi Y, Ohnishi Y.
    Journal: Masui; 1991 Oct; 40(10):1531-5. PubMed ID: 1766102.
    Abstract:
    Leukocyte-depleted blood products are currently a burning issue in transfusion medicine. As methods for depleting leukocytes, the bedside filters are shown to have a high removal rate and several kinds of them are in use. We investigated the leukocytes removal rate of a new filter RC-100 (Pall Co., Glen Cove, NY) under the condition of rapid rate of transfusion during operations. In flow rates of 30, 60, 100 ml.min-1, the removal rate of leukocytes for CRC were 99.9 +/- 0.06, 100.0 +/- 0.00 and 99.4 +/- 0.20% respectively, and for WB 100.0 +/- 0.00, 99.9 +/- 0.10 and 99.1 +/- 0.70%, respectively. The recovery rates of erythrocytes were not significantly decreased for CRC and for WB in all flow rates. These results suggest that RC-100 could be useful either for CRC and for WB even with the rapid flow rate under 100 ml.min-1.
    [Abstract] [Full Text] [Related] [New Search]