These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Endovascular abdominal aortic aneurysm repair in patients with common iliac artery aneurysms--Initial experience with the Zenith bifurcated iliac side branch device.
    Author: Serracino-Inglott F, Bray AE, Myers P.
    Journal: J Vasc Surg; 2007 Aug; 46(2):211-7. PubMed ID: 17664099.
    Abstract:
    OBJECTIVE: To present our initial experience with the Zenith bifurcated iliac side branch device that preserves internal iliac artery flow whilst excluding aorto-iliac aneurysms. METHODS: Between November 2005 and October 2006, data was prospectively collected on 8 patients in whom this device was used; 2 aorto-bi-iliac aneurysms, 3 aorto-uni-iliac aneurysms, 1 solitary common iliac aneurysm, 1 distal type 1 endoleak, and 1 internal iliac aneurysm. RESULTS: No mortality or major complications resulted from use of this device. The median fluoroscopy time was 53 minutes (range 38 to 105) and a median of 102 g of iodine (range 84 to 130) as contrast were used. One patient required a blood transfusion and only one of the eight side branches occluded. There has been no endoleak related to the device in the median follow-up period of 6 months (1 to 14 months). CONCLUSION: This device provides an alternative for the management of patients with aorto-iliac aneurysms that is safe and less complex than, previously described, hybrid procedures that preserve internal iliac flow.
    [Abstract] [Full Text] [Related] [New Search]