These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Combination of two pseudoaneurysms in a patient 6 years after ascending aorta and aortic valve replacement.
    Author: Brat R, Danek T, Maly V.
    Journal: Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2007 Jun; 151(1):125-7. PubMed ID: 17690755.
    Abstract:
    BACKGROUND: We report successful treatment of a patient 6 years after ascending aorta and aortic valve replacement suffering from a combination of two pseudoaneurysms. The first of them originated from the coronary ostial suture line and the second pseudoaneurysm originated from the distal suture line. METHODS: We performed re-replantation of the left main trunk to the prosthesis and then we resected the pseudoaneurysm originating from the distal suture line and we replaced the entire aorta by a vascular graft. RESULTS: The postoperative convalescence was uneventful, the patient was discharged two weeks after the surgery. The patient is currently in a very good condition one year after the surgery. CONCLUSIONS: Coronary ostial pseudoaneurysm in patients after ascending aorta and aortic valve replacement with the use of "button technique" is a quite rare situation. The combination of two pseudoaneurysms originating from different suture lines in one patient seems to be unique in literature reviews.
    [Abstract] [Full Text] [Related] [New Search]