These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Initial experience with directed laser atherectomy using the CLiRpath photoablation atherectomy system and bias sheath in superficial femoral artery lesions.
    Author: Rastan A, Sixt S, Schwarzwälder U, Kerker W, Bürgelin K, Frank U, Noory E, Gremmelmeier D, Branzan D, Hauswald K, Brantner R, Schwarz T, Zeller T.
    Journal: J Endovasc Ther; 2007 Jun; 14(3):365-73. PubMed ID: 17723018.
    Abstract:
    PURPOSE: To report a safety and efficacy study of directed excimer laser atherectomy with the Bias Sheath guiding catheter to create larger lumens in the superficial femoral artery (SFA). METHODS: Fourteen patients (9 men; mean age 66+/-9 years, range 46-76) with chronic lower limb ischemia (Rutherford class 2 to 5) referable to SFA stenoses were treated with the 8-F-compatible Bias Sheath and a 1.7- or 2.0-mm laser catheter. Eight (57%) lesions were de novo and 6 (43%) were in-stent restenoses (ISR). Mean diameter stenosis was 96%+/-8% (range 80%-100%; 10 total occlusions), and mean lesion length was 126+/-78 mm (range 30-290). The primary study endpoint was laser success, defined as <50% angiographic residual stenosis post-laser, without major perforations. RESULTS: The primary endpoint was achieved in 8 (57%) lesions; all patients underwent additional balloon angioplasty, which achieved an angiographic residual stenosis <30% in all. Three lesions could not be completely traversed with the study device. Two dissections were detected after Bias Sheath application; 1 required stenting. There were 2 embolic events (specific to the antegrade device design); both were treated with aspiration therapy. Intravascular ultrasound (IVUS)-based minimal lumen diameters were 0.23+/-0.2 mm (range 0-1.0) at baseline and 3.2+/-0.8 mm after Bias Sheath application. Rutherford category improved at 1 month in 10 (71%) patients. One patient remained unchanged, another worsened (category 2 to 3), 1 died, and the fourth was not examined. The ankle-brachial index improved from 0.41+/-0.18 at baseline to 0.79+/-0.19 at discharge and to 0.80+/-0.19 at 1 month. Primary 1-month patency (<50% restenosis by duplex) was 85% (11/13 lesions). CONCLUSION: SFA lesions, including ISR, can be treated in the majority of cases with directed laser atherectomy, significantly reducing plaque burden as measured by IVUS. Embolization was attributed to device-specific features of the prototype antegrade sheath design, which was discontinued. Larger studies are mandatory to document the long-term technical and clinical impact of this new device.
    [Abstract] [Full Text] [Related] [New Search]