These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Electrochemical behaviour of isatin at a glassy carbon electrode.
    Author: Diculescu VC, Kumbhat S, Oliveira-Brett AM.
    Journal: Anal Chim Acta; 2006 Aug 11; 575(2):190-7. PubMed ID: 17723590.
    Abstract:
    The electrochemical behavior of isatin--a molecule with a broad range of applications in synthetic, biological and clinical activity--has been investigated over a wide pH range at a glassy carbon electrode (GCE) using cyclic, square wave and differential pulse voltammetry. The oxidation of isatin is an irreversible process, pH dependent and occurs with the formation of a main oxidation product that strongly adsorbs on the electrode surface. The reduction of isatin is also a pH dependent irreversible process. Cyclic voltammograms show two consecutive charge transfer reactions. The diffusion coefficient of isatin was calculated in pH 7.0 phosphate buffer to be D(0)=4.9 x 10(-7) cm2 s(-1). The limit of detection obtained in a solution of pH 7.0 phosphate buffer was LOD=0.194 microM, based on three times the noise level.
    [Abstract] [Full Text] [Related] [New Search]