These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparative evaluation of similarity measures for the rigid registration of multi-modal head images. Author: Skerl D, Likar B, Fitzpatrick JM, Pernus F. Journal: Phys Med Biol; 2007 Sep 21; 52(18):5587-601. PubMed ID: 17804883. Abstract: Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR images indicate that mutual information, normalized mutual information and the entropy correlation coefficient are the most accurate similarity measures and have the smallest risk of being trapped in a local optimum. The results of an experiment on the impact of exchanging the floating and target image indicate that, especially in MR/PET registrations, the behavior of some similarity measures, such as mutual information, significantly depends on which image is the floating and which is the target.[Abstract] [Full Text] [Related] [New Search]