Search MEDLINE/PubMed
Title: Electrochemical study of the antineoplastic agent etoposide at carbon paste electrode and its determination in spiked human serum by differential pulse voltammetry. Author: Radi AE, Abd-Elghany N, Wahdan T. Journal: Chem Pharm Bull (Tokyo); 2007 Sep; 55(9):1379-82. PubMed ID: 17827766. Abstract: The electrochemical oxidation of the antineoplastic agent etoposide was studied at carbon paste electrode in Britton-Robinson buffer solutions over the pH range 2.0-10.0 using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug was effected in a single reversible, diffusion-controlled step within the pH range 2.0-4.0, a second oxidation process was produced above pH 4.0. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 3.0 at 0.500 V (vs. Ag/AgCl) on carbon paste electrode. This process could be used to determine etoposide concentrations in the range 2.5 x 10(-7) to 2.5 x 10(-5) M with a detection limit of 1.0 x 10(-7) M. The method was successfully applied to the determination of the drug in spiked human serum.[Abstract] [Full Text] [Related] [New Search]