These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Coagulation function in fresh-frozen plasma prepared with two photochemical treatment methods: methylene blue and amotosalen.
    Author: Osselaer JC, Debry C, Goffaux M, Pineau J, Calomme G, Dubuc E, Chatelain B, Vandendaele MC, Hsu J, Rheinschmidt M, Lin L.
    Journal: Transfusion; 2008 Jan; 48(1):108-17. PubMed ID: 17900283.
    Abstract:
    BACKGROUND: Pathogen inactivation of plasma intended for transfusion is now the standard of care in Belgium. Two methods for treatment of single plasma units are available: amotosalen plus ultraviolet A light and methylene blue plus visible light. This study compared the quality and stability of plasma treated with these two methods. STUDY DESIGN AND METHODS: Plasma units made from a pool of two ABO-matched fresh apheresis units were photochemically treated with either amotosalen (PCT-FFP) or methylene blue (MB-FFP). A total of 12 paired samples were evaluated. Plasma coagulation function was assessed at three time points: immediately after treatment, after 30 days of frozen storage, and an additional 24 hours at 4 degrees C after thawing. Comparison between PCT-FFP and MB-FFP was assessed with the paired t test and a p value of less than 0.05 indicated statistical significance. RESULTS: Based on statistical analysis, mean levels of factor (F)II, FXII, FXIII, von Willebrand antigen, ADAMTS-13, D-dimers, and protein C were equivalent between PCT-FFP and MB-FFP for all three time points. PCT-FFP exhibited shorter mean prothrombin time, activated partial thromboplastin time (two time points), and thrombin time and higher mean levels of fibrinogen, FXI, and protein S than MB-FFP. Retention of FV, FVII, FVIII, FX, or von Willebrand factor:ristocetin cofactor in PCT-FFP was either equivalent to or higher than MB-FFP. MB-FFP contained higher mean levels of plasminogen, antithrombin, and plasmin inhibitor than PCT-FFP. Retention of F IX in MB-FFP was higher than PCT-FFP only after the 4 degrees C storage after thawing. CONCLUSION: There is adequate preservation of therapeutic coagulation factor activities in both PCT-FFP and MB-FFP. The overall coagulation factor levels and stability of PCT-FFP were better preserved than MB-FFP.
    [Abstract] [Full Text] [Related] [New Search]