Title: Attenuation of high-level impulses by earmuffs. Author: Zera J, Mlynski R. Journal: J Acoust Soc Am; 2007 Oct; 122(4):2082-96. PubMed ID: 17902846. Abstract: Attenuation of high-level acoustic impulses (noise reduction) by various types of earmuffs was measured using a laboratory source of type A impulses and an artificial test fixture compatible with the ISO 4869-3 standard. The measurements were made for impulses of peak sound-pressure levels (SPLs) from 150 to 170 dB. The rise time and A duration of the impulses depended on their SPL and were within a range of 12-400 mus (rise time) and 0.4-1.1 ms (A duration). The results showed that earmuff peak level attenuation increases by about 10 dB when the impulse's rise time and the A duration are reduced. The results also demonstrated that the signals under the earmuff cup have a longer rise and A duration than the original impulses recorded outside the earmuff. Results of the measurements were used to check the validity of various hearing damage risk criteria that specify the maximum permissible exposure to impulse noise. The present data lead to the conclusion that procedures in which hearing damage risk is assessed only from signal attenuation, without taking into consideration changes in the signal waveform under the earmuff, tend to underestimate the risk of hearing damage.[Abstract] [Full Text] [Related] [New Search]