These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Electrophysiologic monitoring during surgery to repair the thoraco-abdominal aorta. Author: Sloan TB, Jameson LC. Journal: J Clin Neurophysiol; 2007 Aug; 24(4):316-27. PubMed ID: 17938600. Abstract: Prevention of paraplegia during the repair of thoraco-abdominal aortic aneurysms and dissections present a substantial challenge to the operative team. The value of intraoperative electrophysiological monitoring (IOM) is to identify spinal cord ischemia that occurs during the procedure and guide the intraoperative management to reduce the risks of paralysis. The usefulness of IOM techniques requires an understanding of spinal cord blood flow and the spinal cord physiology, the surgical technique and their interaction. This paper will integrate these factors to review the laboratory and clinical experience with somatosensory evoked responses (SSEP) and motor evoked potentials (MEP) during thoraco-abdominal aorta surgery.[Abstract] [Full Text] [Related] [New Search]