These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Psychophysics of prosthetic vision: I. Visual scanning and visual acuity.
    Author: Chen SC, Hallum LE, Suaning GJ, Lovell NH.
    Journal: Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4400-3. PubMed ID: 17946627.
    Abstract:
    Recipients of vision prosthesis prototypes have reported electrically elicited visual perceptions as discrete dots of light (phosphenes). Phosphenes construct the scenery in discontinuous small isolated patches, resulting in visual information deficit to a large portion of the visual field. Visual scanning therefore plays an important role in the utility of prosthetic vision. In a psychophysical study, normally sighted subjects undertook a visual acuity task in a simulation of prosthetic vision with scanning facilitated by head movements. Subjects who adopted the circular scanning technique (4/12) correctly identified >60% of the test items, compared to subjects with no particular scanning patterns (3/12) with <50%. Increased head movement velocity was correlated to increased performance; at optimal scanning velocities, we estimated a 50% increase in identification rate or a two-fold improvement in visual acuity threshold compared to otherwise complete lack of scanning movement. Improved performance likely resulted from positive interactions with the temporal processes of the human visual system, which may as much as double the spatial information of that originally afforded by the phosphene lattice.
    [Abstract] [Full Text] [Related] [New Search]