These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Hematology patterns after hemoglobin-based oxygen carrier resuscitation from severe controlled hemorrhage with prolonged delayed definitive care.
    Author: Arnaud F, Fasipe D, Philbin N, Rice J, Flournoy WS, Ahlers S, McCarron R, Freilich D.
    Journal: Transfusion; 2007 Nov; 47(11):2098-109. PubMed ID: 17958540.
    Abstract:
    BACKGROUND: The hemoglobin-based oxygen carrier (HBOC-201) resuscitation fluid improves outcome in hemorrhagic shock swine models with minimal coagulopathy. Herein, coagulation parameters were evaluated after resuscitation with HBOC-201 after severe bleeding and prolonged delay to definitive care. STUDY DESIGN AND METHODS: After 55 percent estimated blood volume-controlled hemorrhage by catheter withdrawal, swine (n=48) were resuscitated with HBOC-201 or Hextend (HEX) infused in four doses over 4 hours or not resuscitated (NON). Animals were randomly assigned in two cohorts of 4- or 24-hour simulated delay to hospital arrival (access to blood and saline infusions up to 72 hr). In vitro hematologic monitoring was assessed with complete blood count, hemostasis (thromboelastography [TEG], in vitro bleeding time [PFA]), and coagulation (prothrombin time [PT], thrombin-antithrombin, fibrinogen) indices. RESULTS: Within groups, survival was unaffected by extending delay from 4 to 24 hours. Combined survival was similar for HBOC-201 and HEX but lower for NON animals (93.5, 81.5, and 25 percent, respectively; p<0.01). Blood transfusion requirements were lower with HBOC-201 than HEX. Elevated TEG and PFA parameters in resuscitated animals reflected fluid and blood transfusion regimens. TEG reaction time and PFA were transiently higher with HBOC-201 than with HEX during the early hospital phase. PT was increased in HEX animals. CONCLUSION: In this severe model, survival was equivalent with HBOC-201 and HEX resuscitation. HBOC-201 or HEX allowed delayed hospital arrival to 24 hours without worsening coagulation parameters, but dilutional mild coagulopathy in the hospital phase persisted with HBOC-201 due to blood transfusion avoidance. Low hematocrit suggests that blood administration after HBOC-201 resuscitation could be beneficial to replete blood cellular mass.
    [Abstract] [Full Text] [Related] [New Search]