These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation Clinical comparative study.
    Author: Tzelikis PF, Akaishi L, Trindade FC, Boteon JE.
    Journal: J Cataract Refract Surg; 2007 Nov; 33(11):1918-24. PubMed ID: 17964398.
    Abstract:
    PURPOSE: To determine whether implantation of an intraocular lens (IOL) with a modified posterior aspherical surface (AcrySof IQ, Alcon Surgical Laboratories) results in reduced ocular aberrations (spherical aberration) and improved contrast sensitivity after cataract surgery. SETTING: Brasilia Ophthalmologic Hospital, Brasilia, and Sao Geraldo Eye Hospital, Federal University of Minas Gerais, Belo Horizonte, Brazil. METHODS: In an intraindividual randomized prospective study of 25 patients with bilateral cataract, an IOL with a modified posterior surface (AcrySof IQ) was compared with a biconvex IOL with spherical surfaces (AcrySof Natural, Alcon). Ocular aberrations with a 5.0 mm and 6.0 mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured by visual acuity and contrast sensitivity under mesopic and photopic conditions. All patients were followed for 3 months. RESULTS: There were no statistically significant differences between eyes in postoperative uncorrected and best corrected distance visual acuities after a follow-up of 1 month and 3 months. Postoperatively, there was a statistically significant between-group difference in contrast sensitivity under photopic conditions without glare at 18 cycles per degree (cpd) (P = .04) and under mesopic conditions without glare at all spatial frequencies (3 cpd, 6 cpd, 12 cpd, and 18 cpd; P = .03, P = .009, P = .003, and P = .003, respectively) and with glare at 3 cpd and 6 cpd (P = .001 and P = .02, respectively). The difference in higher-order aberration (HOA) values between groups was statistically significant with a 5.0 mm and 6.0 mm pupil, with the AcrySof IQ IOL inducing less HOA than the AcrySof Natural IOL. Eyes with an AcrySof IQ IOL also had statistically significant less spherical aberration than eyes with an AcrySof Natural IOL with both pupil diameters (P<.001). CONCLUSIONS: The AcrySof IQ IOL with a modified posterior surface induced significantly less HOA and spherical aberration than the AcrySof Natural IOL. Contrast sensitivity was better under mesopic conditions with the AcrySof IQ IOL.
    [Abstract] [Full Text] [Related] [New Search]