These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Assessment of serological assays for the diagnosis of HIV-1 infections.
    Author: Danaby RS, Constantine NT, Daise RL, Watts DM.
    Journal: J Egypt Public Health Assoc; 1991; 66(5-6):477-90. PubMed ID: 1797961.
    Abstract:
    Many serologic techniques are available for the detection of HIV-1 infection, but their diagnostic performances have been reported to vary depending on the testing situations. We evaluated eight different serologic assays for detecting HIV-1 antibody in sera from suspected high risk groups in North and East Africa. These included: one ELISA bead assay, three indirect ELISAs, two competitive ELISA assays, one gelatin agglutination assay and a recombinant dot-blot assay. A panel of 38 HIV-1 antibody confirmed positive human sera and a panel of 60 HIV negative sera were tested. All sera yielding discordant results were retested for verification of reactivity. Among the different assays evaluated for detecting HIV-1 antibody, sensitivities ranged from 0.919 to 0.974 and test efficiencies ranged from 94.2-98.9%. All assays failed to detect at least one western blot confirmed positive serum; three tests (Organon, DuPont recombinant and Serodia) produced only one false-negative result. Five of the eight assays did not produce any false-positive results. The Organon viral lysate and the DuPont recombinant ELISAs exhibited the best overall performance (test efficiency = 98.9%).
    [Abstract] [Full Text] [Related] [New Search]