  • Title: Capillary immunotyping electrophoresis and high resolution two-dimensional electrophoresis for the detection of mu-heavy chain disease.
    Author: Maisnar V, Tichy M, Stulik J, Urban P, Adam Z, Kadlckova E, Vavrova J, Palicka V, Jebavy L, Kodet R, Buchler T, Hajek R.
    Journal: Clin Chim Acta; 2008 Mar; 389(1-2):171-3. PubMed ID: 18036562.
    Abstract:
    Heavy chain disease with monoclonal incomplete mu-heavy chains (mu-HCD) is a rare disorder usually associated with an underlying lymphoproliferative malignancy. Laboratory diagnosis of patients with mu-HCD is usually challenging and the monoclonal protein is not detected by electrophoresis in up to 75% of mu-HCD cases. We describe a patient with multiple malignancies in whom we detected and characterized monoclonal mu-heavy chains using immunofixation electrophoresis, capillary zone electrophoresis with immunotyping, and high resolution two-dimensional electrophoresis. The high resolution 2D electrophoresis enabled us to determine the molecular weight of the mu-heavy chains. The abnormal protein concentration in the serum was unusually high, 38 g/l measured in our patient is the highest reported value in the literature so far.
    [Abstract] [Full Text] [Related] [New Search]