These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Brillouin-based fiber-optic distributed temperature sensor with optical preamplification. Author: De Souza K, Newson TP. Journal: Opt Lett; 2000 Sep 15; 25(18):1331-3. PubMed ID: 18066207. Abstract: Optical preamplification has been used in a fiber-optic distributed temperature sensor based on spontaneous Brillouin scattering and the use of direct detection, resulting in improved signal-to-noise ratios. The fiber-based optical preamplifier system comprises a three-port circulator, an erbium-doped fiber amplifier with a small-signal gain of 27 dB, and a fiber Bragg grating with 47-GHz bandwidth. An improvement of 17 dB in the optical signal-to-noise ratio for the Brillouin signal is demonstrated in a 23-km sensor. The limit to the signal-to-noise ratio is attributed to spontaneous-spontaneous beat noise generated at the photodetector by amplified spontaneous emission from the optical amplifier.[Abstract] [Full Text] [Related] [New Search]