These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of urinary phytoestrogens by HPLC-MS/MS: a comparison of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI).
    Author: Rybak ME, Parker DL, Pfeiffer CM.
    Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jan 01; 861(1):145-50. PubMed ID: 18068558.
    Abstract:
    A comparison of the analytical performance of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) for the quantitative determination of six urinary phytoestrogens (daidzein, O-desmethylangolensin, equol, enterodiol, enterolactone and genistein) by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is presented here. Both APCI and ESI were suitable for the analysis of these compounds; however, ESI did improve measurement imprecision and sensitivity in certain cases. Method imprecision (between-run coefficients of variation [CVs] from duplicate analysis of three quality control [QC] urine pools across 20 runs) was 5.6-12% for ESI, as opposed to 5.3-30% for APCI. At low concentrations (3-60 ng/mL, analyte dependent) imprecision was lower with ESI, whereas both techniques were generally commensurate at high concentrations (200-1000 ng/mL, analyte dependent). Method accuracy (spiked analyte recovery from the QC pools) was comparable between techniques: 86-114% for ESI; 95-105% for APCI. Limits of detection (LODs) were equivalent or better with ESI compared to APCI, with the most significant LOD improvement observed for equol (ESI: 0.3 ng/mL; APCI: 2.7 ng/mL). This translated into a substantial increase in equol detection frequency (% of sample results above LOD) within a random patient sample subset (98% for ESI, compared to 81% for APCI, n=378). Correlation (Pearson) and agreement (Deming regression, Bland-Altman bias) between ESI and APCI results in the patient subset was better in cases where imprecision and sensitivity was similar for both techniques (daidzein, enterolactone, genistein: r=0.993-0.998; slope=0.98-1.03; bias=-4.2 to -0.8%); correlation and/or agreement was poorer for analytes, where APCI imprecision and sensitivity were inferior (equol, O-desmethylangolensin, enterodiol). Baring significant factors arising from differences in ionization source design, these observations suggest that ESI is more appropriate for urinary biomonitoring of these compounds by LC-MS/MS.
    [Abstract] [Full Text] [Related] [New Search]