These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment. Author: De Zan MM, Gil García MD, Culzoni MJ, Siano RG, Goicoechea HC, Martínez Galera M. Journal: J Chromatogr A; 2008 Feb 01; 1179(2):106-14. PubMed ID: 18093603. Abstract: The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (MCR-ALS) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C18 150 mm x 4.6mm (5 microm particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r2 = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers. MCR-ALS was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse.[Abstract] [Full Text] [Related] [New Search]