These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer.
    Author: Lindegaard JC, Tanderup K, Nielsen SK, Haack S, Gelineck J.
    Journal: Int J Radiat Oncol Biol Phys; 2008 Jul 01; 71(3):756-64. PubMed ID: 18191335.
    Abstract:
    PURPOSE: To compare dose-volume histogram parameters of standard Point A and magnetic resonance imaging-based three-dimensional optimized dose plans in 21 consecutive patients who underwent pulsed-dose-rate brachytherapy (PDR-BT) for locally advanced cervical cancer. METHODS AND MATERIALS: All patients received external beam radiotherapy (elective target dose, 45 Gy in 25-30 fractions; tumor target dose, 50-60 Gy in 25-30 fractions). PDR-BT was applied with a tandem-ring applicator. Additional ring-guided titanium needles were used in 4 patients and a multichannel vaginal cylinder in 2 patients. Dose planning was done using 1.5 Tesla T(1)-weighted and T(2)-weighted paratransversal magnetic resonance imaging scans. T(1)-weighted visible oil-containing tubes were used for applicator reconstruction. The prescribed standard dose for PDR-BT was 10 Gy (1 Gy/pulse, 1 pulse/h) for two to three fractions to reach a physical dose of 80 Gy to Point A. The total dose (external beam radiotherapy plus brachytherapy) was normalized to an equivalent dose in 2-Gy fractions using alpha/beta = 10 Gy for tumor, alpha/beta = 3 Gy for normal tissue, and a repair half-time of 1.5 h. The goal of optimization was dose received by 90% of the target volume (D(90)) of > or =85 Gy(alpha/beta10) in the high-risk clinical target volume (cervix and remaining tumor at brachytherapy), but keeping the minimal dose to 2 cm(3) of the bladder and rectum/sigmoid at <90 and <75 Gy(alpha/beta3), respectively. RESULTS: Using three-dimensional optimization, all dose-volume histogram constraints were met in 16 of 21 patients compared with 3 of 21 patients with two-dimensional library plans (p < 0.001). Optimization increased the minimal target dose (D(100)) of the high-risk clinical target volume (p < 0.007) and decreased the minimal dose to 2 cm(3) for the sigmoid significantly (p = 0.03). For the high-risk clinical target volume, D(90) was 91 +/- 8 Gy(alpha/beta10) and D(100) was 76 +/- 5 Gy(alpha/beta10). The minimal dose to 2 cm(3) for the bladder, rectum, and sigmoid was 73 +/- 6, 67 +/- 6, and 69 +/- 6 Gy(alpha/beta3), respectively. CONCLUSION: The results of our study have shown that magnetic resonance imaging-guided optimization of PDR-BT for locally advanced cervical cancer significantly improved the dose-volume histogram parameters.
    [Abstract] [Full Text] [Related] [New Search]