These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A sweeping-micellar electrokinetic chromatography method for direct detection of some aromatic amines in water samples. Author: Zhang J, Wu X, Zhang W, Xu L, Chen G. Journal: Electrophoresis; 2008 Feb; 29(4):796-802. PubMed ID: 18203255. Abstract: A simple and rapid sweeping method for the online improvement of detection limit of some aromatic amines has been developed in this work. The optimum sweeping and separation conditions for 4-methylaniline, 3,4-dichloroaniline, 4-chloroaniline, and 4-aminophenyl were investigated in detail. Under the optimum conditions, the detection limits of these four aromatic amines ranged from 5.4 x 10(-10) to 4.6 x 10(-8)mol/L (S/N = 3), which was about 80-1090-folds lower than those of conventional sample injections. Linear response range were in the range of 2.5 x 10(-8)-2.0 x 10(-6)mol/L with the correlation coefficient between 0.9965 and 0.9994. Baseline separation was achieved within 10 min. After validation, the developed method was applied to determine 4-methylaniline, 3,4-dichloroaniline, 4-chloroaniline, and 4-aminophenyl in river water sample with average recoveries of 79.6-88.7%.[Abstract] [Full Text] [Related] [New Search]