These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Preliminary outcomes of the SmartWheel Users' Group database: a proposed framework for clinicians to objectively evaluate manual wheelchair propulsion.
    Author: Cowan RE, Boninger ML, Sawatzky BJ, Mazoyer BD, Cooper RA.
    Journal: Arch Phys Med Rehabil; 2008 Feb; 89(2):260-8. PubMed ID: 18226649.
    Abstract:
    OBJECTIVES: To describe a standard clinical protocol for the objective assessment of manual wheelchair propulsion; to establish preliminary values for temporal and kinetic parameters derived from the protocol; and to develop graphical references and a proposed application process for use by clinicians. DESIGN: Case series. SETTING: Six research institutions that collect kinetic wheelchair propulsion data and contribute that data to an international data pool. PARTICIPANTS: Subjects with spinal cord injury (N=128). INTERVENTIONS: Subjects propelled a wheelchair from a stationary position to a self-selected velocity across a hard tile surface, a low pile carpet, and up an Americans with Disabilities Act-compliant ramp. Unilateral kinetic data were obtained from subjects using a force and moment sensing pushrim. MAIN OUTCOME MEASURES: Differences in self-selected velocity, peak resultant force, push frequency, and stroke length across all surfaces, relationship between (1) weight-normalized peak resultant force and self-selected velocity and (2) push frequency and self-selected velocity. RESULTS: Graphical references were generated for potential clinical use based on the relation between body weight-normalized peak resultant force, push frequency, and velocity. Self-selected velocity decreased (ramp < carpet < tile), peak resultant forces increased (ramp > carpet > tile), and push frequency and stroke length remained unchanged when compared across the different surfaces. Weight-normalized peak resultant force was a significant predictor of velocity on tile and ramp. Push frequency was a significant predictor of velocity on tile, carpet, and ramp. CONCLUSIONS: We present preliminary data generated from a clinically practical manual wheelchair propulsion evaluation protocol and we describe a proposed method for clinicians to objectively evaluate manual wheelchair propulsion.
    [Abstract] [Full Text] [Related] [New Search]