These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Design and evaluation of a multi-detection system composed of ultraviolet, evaporative light scattering and inductively coupled plasma mass spectrometry detection for the analysis of pharmaceuticals by liquid chromatography.
    Author: Pereira AS, Schelfaut M, Lynen F, Sandra P.
    Journal: J Chromatogr A; 2008 Mar 21; 1185(1):78-84. PubMed ID: 18262535.
    Abstract:
    Reversed-phase liquid chromatography was coupled to a multi-detection system composed of ultraviolet (UV) detection, evaporative laser scattering detection (ELSD) and inductively coupled plasma mass spectrometry (ICP-MS). By applying the principle of post-column solvent compensation, the organic modifier content was kept constant in ELSD and ICP-MS under gradient elution. Chlorine ((35)Cl), bromine ((79)Br and (81)Br) and sulfur ((34)S) were monitored in several pharmaceutical compounds. The limit of quantitation (LOQ) was 80 ng/mL for chlorine (chlorpropamide) and 2 ng/mL for bromine (bromazepam). Calibration graphs were linear from 1.0 microg/mL to 100 microg/mL for chlorpropamide (r(2) 0.990) and from 10 ng/mL to 500 ng/mL for bromazepam (r(2) 0.996). The low LOQ value for bromine allows to quantify bromine in pharmaceutical samples below the 0.05% level of the active pharmaceutical ingredient.
    [Abstract] [Full Text] [Related] [New Search]