These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Simultaneous use of gas chromatography/ion trap mass spectrometry - electron capture detection to improve the analysis of bromodiphenyl ethers in biological and environmental samples.
    Author: Wang D, Atkinson S, Hoover-Miller A, Shelver WL, Li QX.
    Journal: Rapid Commun Mass Spectrom; 2008; 22(5):647-56. PubMed ID: 18265429.
    Abstract:
    Bromodiphenyl ethers (BDEs) are a class of synthetic flame retardants and are widely present in the environment. Analysis of higher BDE congeners has proven to be a challenge. We report the development of a method that enhances their analysis by splitting the eluent of a gas chromatograph (GC) between an electron capture detector (ECD) and an ion trap mass spectrometer (ITMS): 1:10, ECD:ITMS. This allowed the quantitation of the lower molecular weight (MW) BDE congeners (Br1-Br7) with the ITMS and of the higher MW BDEs (Br8-Br10) with the highly sensitive ECD. The IT temperature, ionization mode, and MS/MS parameters (excitation amplitude and stability parameter) were optimized. This method took the advantages of the best detector for the different BDE homologues and was suitable for the analysis of BDEs in environmental and biological samples. Average recoveries were 52-112% for BDEs from spiked sand samples and 57-126% from spiked lard samples after accelerated solvent extraction followed by silica gel and alumina column clean-up. Average recoveries ranged from 51% to 130% for 13C-labeled BDEs spiked in the real and in matrix samples. The method detection limits for specific congeners were 0.18-120 pg/g of the BDEs in animal tissue samples, and 0.05-40 pg/g in soil and indoor dust samples. The utility of the method was demonstrated by analyzing actual harbor seal blubber, indoor dust and soil samples. The concentration of each BDE ranged from non-detectable (nd) to 41 ng/g in the dry soil sample, nd to 1042 ng/g in the indoor dust, nd to 15 ng/g wet weight in the Alaskan harbor seal blubber sample, and 0.02 to 11 ng/microL of the identified 23 of the 42 breakdown products from BDE-209 after zerovalent iron treatment. Finally, an interlaboratory comparison showed high correspondence between the GC/ITMS-ECD method and a GC high-resolution MS system for the analysis of BDEs in soil samples.
    [Abstract] [Full Text] [Related] [New Search]