These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Effectiveness of recombinant desulphatohirudin in reducing restenosis after balloon angioplasty of atherosclerotic femoral arteries in rabbits.
    Author: Sarembock IJ, Gertz SD, Gimple LW, Owen RM, Powers ER, Roberts WC.
    Journal: Circulation; 1991 Jul; 84(1):232-43. PubMed ID: 1829399.
    Abstract:
    BACKGROUND: The effectiveness of balloon angioplasty is limited by a restenosis rate of approximately 30%. Recombinant desulphatohirudin (r-hirudin [CGP 39393]) has been found to be highly effective in preventing acute platelet-rich thrombosis after deep arterial injury as compared with heparin. METHODS AND RESULTS: This study evaluated the effect of intravenous r-hirudin, a selective inhibitor of thrombin, on restenosis after balloon angioplasty in 29 rabbits. Focal femoral atherosclerosis was induced by air desiccation endothelial injury followed by a 2% cholesterol diet for 1 month. At angioplasty (2.5-mm balloon with three 60-second, 10-atm inflations 60 seconds apart), the rabbits received heparin (150 units/kg bolus, n = 16) or r-hirudin (1 mg/kg bolus followed by infusions of 1 mg/kg for the first hour and 0.5 mg/kg for the second hour, n = 13). Angiograms performed before and after angioplasty and before death were analyzed quantitatively by a blinded observer. Rabbits were killed 2 hours (n = 14) or 28 days (n = 15) after angioplasty. Femoral arteries were fixed in situ by perfusion of 10% formaldehyde at 100 mm Hg. The mean luminal diameter of the arteries with successful angioplasty (greater than or equal to 20% increase in luminal diameter) in rabbits treated with heparin (n = 8 arteries) increased from 1.18 +/- 0.29 mm before angioplasty to 1.86 +/- 0.24 mm immediately after angioplasty (p less than 0.001) and decreased to 0.94 +/- 0.69 mm (p = 0.0004) at 28 days after angioplasty. In rabbits treated with r-hirudin (n = 11 arteries), the mean luminal diameter increased from 1.14 +/- 0.17 mm before angioplasty to 1.68 +/- 0.20 mm immediately after angioplasty (p less than 0.001) and decreased to 1.37 +/- 0.47 mm (p = 0.01) at 28 days after angioplasty. The mean reduction in luminal diameter by angiography was less in the r-hirudin-treated group than in the heparin-treated group (0.30 +/- 0.33 versus 0.92 +/- 0.61 mm, p = 0.01). Blinded planimetric analysis of stained histological sections of the femoral arteries also showed less cross-sectional area narrowing by plaque in rabbits treated with r-hirudin compared with those treated with heparin (22 +/- 16% verus 48 +/- 29%, p = 0.01). Both groups had similar numbers of arteries with histological evidence of balloon-induced plaque tear (12 of 13 versus 13 of 15). CONCLUSIONS: Rabbits receiving r-hirudin at the time of experimental balloon angioplasty had significantly less restenosis by angiography and by quantitative histopathology than rabbits receiving heparin.
    [Abstract] [Full Text] [Related] [New Search]