These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A new technique for time-resolved daughter ion mass spectrometry on the microsecond to millisecond time scale using an electrostatic ion storage ring.
    Author: Støchkel K, Kadhane U, Andersen JU, Holm AI, Hvelplund P, Kirketerp MB, Larsen MK, Lykkegaard MK, Nielsen SB, Panja S, Zettergren H.
    Journal: Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):023107. PubMed ID: 18315283.
    Abstract:
    A new method for time-resolved daughter ion mass spectrometry is presented, based on the electrostatic ion storage ring in Aarhus, ELISA. Ions with high internal energy, e.g., as a result of photoexcitation, dissociate and the yield of neutrals is monitored as a function of time. This gives information on lifetimes in the microsecond to millisecond time range but no information on the fragment masses. To determine the dissociation channels, we have introduced pulsed supplies with switching times of a few microseconds. This allows rapid switching from storage of parent ions to storage of daughter ions, which are dumped into a detector after a number of revolutions in the ring. A fragment mass spectrum is obtained by monitoring the daughter ion signal as a function of the ring voltages. This technique allows identification of the dissociation channels and determination of the time dependent competition between these channels.
    [Abstract] [Full Text] [Related] [New Search]