These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Gadobenate dimeglumine as a contrast agent for dynamic breast magnetic resonance imaging: effect of higher initial enhancement thresholds on diagnostic performance.
    Author: Sardanelli F, Fausto A, Esseridou A, Di Leo G, Kirchin MA.
    Journal: Invest Radiol; 2008 Apr; 43(4):236-42. PubMed ID: 18340247.
    Abstract:
    RATIONALE AND OBJECTIVE: Gadobenate dimeglumine (Gd-BOPTA), a high-relaxivity contrast agent, has been recently proposed for dynamic MR imaging of the breast. The objective of this study was to optimize the diagnostic performance of Gd-BOPTA-enhanced dynamic breast MR imaging by using adjusted initial enhancement thresholds. METHODS: Thirty-four patients with 36 breast lesions (malignant/benign = 28/8) underwent dynamic breast MRI with 0.1 mmol/kg Gd-BOPTA and 120-second time resolution. A score system based on shape (round/oval/lobular = 0; linear/dendritic/stellate = 1), margins (defined = 0; undefined = 1), pattern (homogeneous = 0; inhomogeneous = 1; rim = 2), kinetics (continuous = 0; plateau = 1; washout = 2), and initial enhancement was used. Initial enhancement was determined with standard (<50% = 0; 50%-100% = 1; >100% = 2) and adjusted (<100% = 0; 100%-240% = 1; >240% = 2) thresholds. Scores of 0 to 3 indicated benign lesions and scores of 4 to 8 malignant lesions. Diagnostic performance was assessed in terms of sensitivity, specificity, positive and negative predictive values, and overall accuracy. RESULTS: The initial enhancement was >100% for 26 malignant and 7 benign lesions and >240% for 16 and 1 lesions, respectively. The overall score was 5.89 +/- 1.34 with standard thresholds and 5.50 +/- 1.53 with adjusted thresholds (P = 0.003) for cancers, 4.00 +/- 1.93 and 3.25 +/- 1.75 (P = 0.028) for benign lesions, respectively. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 96%, 13%, 79%, 50%, and 78%, respectively, with standard thresholds and 96%, 75%, 93%, 86%, and 92%, respectively, with adjusted thresholds. A ductal carcinoma in situ was false negative whereas a fat necrosis and a papilloma were false positive with both thresholds. Three fibroadenomas, 1 adenosis, and 1 fibrosis were false positive with standard thresholds but true negatives with adjusted thresholds. CONCLUSIONS: Lesion characterization with Gd-BOPTA requires higher thresholds for initial enhancement than those used with conventional Gd-chelates, leading to improved specificity, predictive values, and accuracy.
    [Abstract] [Full Text] [Related] [New Search]