These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Spillover and partial-volume correction for image-derived input functions for small-animal 18F-FDG PET studies.
    Author: Fang YH, Muzic RF.
    Journal: J Nucl Med; 2008 Apr; 49(4):606-14. PubMed ID: 18344438.
    Abstract:
    UNLABELLED: We present and validate a method to obtain an input function from dynamic image data and 0 or 1 blood sample for small-animal 18F-FDG PET studies. The method accounts for spillover and partial-volume effects via a physiologic model to yield a model-corrected input function (MCIF). METHODS: Image-derived input functions (IDIFs) from heart ventricles and myocardial time-activity curves were obtained from 14 Sprague-Dawley rats and 17 C57BL/6 mice. Each MCIF was expressed as a mathematic equation with 7 parameters, which were estimated simultaneously with the myocardial model parameters by fitting the IDIFs and myocardium curves to a dual-output compartment model. Zero or 1 late blood sample was used in the simultaneous estimation. MCIF was validated by comparison with input measured from blood samples. Validation included computing errors in the areas under the curves (AUCs) and in the 18F-FDG influx constant Ki in 3 types of tissue. RESULTS: For the rat data, the AUC error was 5.3% +/- 19.0% in the 0-sample MCIF and -2.3% +/- 14.8% in the 1-sample MCIF. When the MCIF was used to calculate the Ki of the myocardium, brain, and muscle, the overall errors were -6.3% +/- 27.0% in the 0-sample method (correlation coefficient r = 0.967) and 3.1% +/- 20.6% in the 1-sample method (r = 0.970). The t test failed to detect a significant difference (P > 0.05) in the Ki estimates from both the 0-sample and the 1-sample MCIF. For the mouse data, AUC errors were 4.3% +/- 25.5% in the 0-sample MCIF and -1.7% +/- 20.9% in the 1-sample MCIF. Ki errors averaged -8.0% +/- 27.6% for the 0-sample method (r = 0.955) and -2.8% +/- 22.7% for the 1-sample method (r = 0.971). The t test detected significant differences in the brain and muscle in the Ki for the 0-sample method but no significant differences with the 1-sample method. In both rat and mouse, 0-sample and 1-sample MCIFs both showed at least a 10-fold reduction in AUC and Ki errors compared with uncorrected IDIFs. CONCLUSION: MCIF provides a reliable, noninvasive estimate of the input function that can be used to accurately quantify the glucose metabolic rate in small-animal 18F-FDG PET studies.
    [Abstract] [Full Text] [Related] [New Search]