  • Title: Percutaneous balloon valvuloplasty of coexisting mitral and tricuspid stenosis: single-wire, double-balloon technique.
    Author: Ashraf T, Pathan A, Kundi A.
    Journal: J Invasive Cardiol; 2008 Apr; 20(4):E126-8. PubMed ID: 18398244.
    Abstract:
    BACKGROUND: Percutaneous transmitral commissurotomy (PTMC) was first described by Inoue as an alternative to surgical closed mitral commissurotomy for severe rheumatic mitral stenosis. Two techniques - single- and double-balloon methods and percutaneous metallic devices - have been described for mitral dilatation. The Multi-Track system, a single-wire, double-balloon device was introduced by Bonhoeffer for mitral valve dilatation. We describe a case of mitral and tricuspid valve dilatation employing this double-balloon technique. METHODS: A 25-year-old male with combined rheumatic mitral and tricuspid stenosis and severe pulmonary hypertension underwent simultaneous double-valve dilatation in a single setting using different sizes of the Multi-Track balloon catheter. RESULTS: The patient's transmitral gradient decreased from 15 to 2 mmHg and his mitral valve area increased from 1 cm(2) to 2.2 cm(2). Similarly, his tricuspid valve gradient dropped from 7 to 3 mmHg and his tricuspid valve area increased from 0.9 cm(2) to 3.0 cm(2). CONCLUSION: Percutaneous balloon valvuloplasty using the Multi-Track system for combined mitral and tricuspid stenosis is cost effective and simple to use.