These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Early goal-directed therapy (EDGT) using continuous central venous oxygen saturation monitoring in a patient with septic shock]. Author: Oyama Y, Goto K, Yamamoto S, Kusaka J, Hidaka S, Shingu C, Noguchi T. Journal: Masui; 2008 Apr; 57(4):443-6. PubMed ID: 18416200. Abstract: Septic shock is an adverse clinical condition resulting in multiple organ failure from global tissue hypoxia. The importance of initial treatment is widely recognized. Thus, guidelines for septic shock recommend early goal-directed therapy (EGDT) during the first six hours of treatment. Central venous oxygen saturation monitoring is useful to maintain adequate tissue oxygen delivery. A newly developed central venous oximetry catheter (PreSep Oximetery Catheter, Edwards Lifesciences) allows continuous and easy monitoring of central venous oxygen saturation. This report shows the usefulness of this catheter in a patient who developed septic shock during an emergency operation for perforated bowel. By using EGDT perioperatively with continuous central venous oximetry, multiple organ failure might be successfully avoided.[Abstract] [Full Text] [Related] [New Search]