These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical experience with a new superelastic Ni-Ti-stainless steel retraction spring.
    Author: Skoularikis P, Wichelhaus A, ent PD, Sander FG.
    Journal: World J Orthod; 2008; 9(1):48-51. PubMed ID: 18426105.
    Abstract:
    This article describes the clinical application of a new superelastic Ni-Ti-stainless steel retraction spring used especially for canine retraction following the segmented archwire technique. The use of the new spring and its 2 configurations are demonstrated in a typodont experiment. Clinical experience with the new spring is presented in 2 patients; it produced canine retraction in these patients who required first premolar extraction. The use of the spring in both cases led to bodily tooth retraction without reactivation or any undesirable side effects.
    [Abstract] [Full Text] [Related] [New Search]