These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Successful radiofrequency catheter ablation of ventricular tachycardia originating from underneath the mechanical prosthetic aortic valve. Author: Yamada T, McElderry HT, Doppalapudi H, Kay GN. Journal: Pacing Clin Electrophysiol; 2008 May; 31(5):618-20. PubMed ID: 18439180. Abstract: A 67-year-old man who developed sustained ventricular tachycardia (VT) 4 years after a prosthetic aortic valve replacement, underwent electrophysiologic testing and catheter ablation. The mechanism of the VT was suggested to be triggered activity because the VT could be induced by programmed ventricular stimulation, and burst ventricular pacing demonstrated overdrive suppression without a transient entrainment. Successful catheter ablation using a transseptal approach was achieved underneath the mechanical prosthetic aortic valve on the blind side for that approach. This case demonstrated that catheter mapping and ablation of the entire LV using a transseptal approach might be possible.[Abstract] [Full Text] [Related] [New Search]