These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Position of interbody spacer in transforaminal lumbar interbody fusion: effect on 3-dimensional stability and sagittal lumbar contour. Author: Faundez AA, Mehbod AA, Wu C, Wu W, Ploumis A, Transfeldt EE. Journal: J Spinal Disord Tech; 2008 May; 21(3):175-80. PubMed ID: 18458586. Abstract: STUDY DESIGN: Biomechanical study. OBJECTIVE: To test 2 different intervertebral positions of a semilunar cage and their effects on 3-dimensional stability and segmental lordosis in a model of transforaminal lumbar interbody fusion (TLIF). SUMMARY OF BACKGROUND DATA: In his original TLIF description, Harms recommended decortication of endplates, followed by placement of mesh cages in the middle-posterior intervertebral third. Subsequent studies presented conflicting recommendations: anterior placement of the spacer-cage for better load-sharing versus placement on the stronger posterolateral endplate regions. METHODS: Six human lumbar spinal functional units were first tested intact. TLIF was performed using a semilunar poly-ether-ether-ketone cage randomly inserted in the anterior (TLIF-A) or posterior (TLIF-P) disc space. Pedicle screws and rods were added. Unconstrained pure moments in axial-torsion, lateral-bending (LB), and flexion-extension (FE) were applied under 0.05 Hz and +/-5 Nm sinusoidal waveform. Segmental motions were recorded. Range of motion (ROM) and neutral zone (NZ) were calculated. Pairwise comparisons were made using nonparametric Wilcoxon-matched pairs signed rank sum test with statistical significance set at P<0.05. RESULTS: TLIF-A and TLIF-P significantly decreased ROM (P<0.05) of the intact spinal functional unit, in FE and LB. In axial-torsion, decrease of ROM after TLIF procedures was not significant (P>0.05). Delta-ROM between TLIF-A and TLIF-P was not significant (P>0.05). TLIF-A and TLIF-P significantly decreased NZ in LB (P<0.05). In FE, TLIF-P significantly decreased NZ (P<0.05); TLIF-A showed a trend toward significance (P=0.09). Delta-NZ between TLIF-A and TLIF-P was not significant (P>0.05). Segmental lordosis of TLIF-A and TLIF-P on C-arm views showed angle differences within the range of measurement error of Cobb angles. CONCLUSIONS: Difference in ROM and NZ between anterior (TLIF-A) or posterior (TLIF-P) positions was not statistically significant. Similarly, both positions did not influence segmental lordosis.[Abstract] [Full Text] [Related] [New Search]