  • Title: Direct uterine sampling with the Tao brush sampler using a liquid-based preparation method for the detection of endometrial cancer and atypical hyperplasia: a feasibility study.
    Author: Kipp BR, Medeiros F, Campion MB, Distad TJ, Peterson LM, Keeney GL, Halling KC, Clayton AC.
    Journal: Cancer; 2008 Aug 25; 114(4):228-35. PubMed ID: 18548528.
    Abstract:
    BACKGROUND: Endometrial cytology sampling devices for direct uterine sampling have been shown in previous studies to be a reliable and relatively painless method for detecting endometrial lesions. The purpose of the current study was to determine the performance characteristics of endometrial cytology for the detection of malignancy and atypical hyperplasia using liquid-based cytology specimens collected with the Tao brush sampler. METHODS: Brushings of the endometrial cavity were obtained from 139 hysterectomy specimens before routine histopathologic evaluation. Cytology specimens were fixed in PreservCyt and processed using ThinPrep technology. Cytology diagnoses were classified as nondiagnostic, negative, atypical, or positive for malignancy. Histopathologic findings were used as the gold standard for determining the performance characteristics of cytology. RESULTS: Histopathologic results from the 139 patients included 81 (58%) endometrial cancers, 7 (5%) complex hyperplasias with atypia, 2 (1%) complex hyperplasias without atypia, and 49 (35%) patients with benign histology. The number of specimens diagnosed cytologically as positive, atypical, negative, or nondiagnostic was 60 (43%), 40 (29%), 37 (27%), and 2 (1%) specimens, respectively. The overall sensitivity and specificity of cytology for detecting endometrial cancer and atypical hyperplasia were 95% and 66% when atypical cytology specimens were considered positive. CONCLUSIONS: The results of the current study indicate that direct endometrial sampling by liquid-based endometrial cytology collected with the Tao brush sampler produces specimens that contain cellular material that may be identified as endometrial cancer or atypical hyperplasia. Both atypical and positive cytology diagnoses are indicators for triage to more specific methods of diagnosis.
    [Abstract] [Full Text] [Related] [New Search]