These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Total-skin electron irradiation for cutaneous T-cell lymphoma: the Northern Israel Oncology Center experience. Author: Kuten A, Stein M, Mandelzweig Y, Tatcher M, Yaacov G, Epelbaum R, Rosenblatt E. Journal: Strahlenther Onkol; 1991 Jul; 167(7):392-6. PubMed ID: 1858014. Abstract: Total-skin electron irradiation (TSEI) is effective and frequently used in the treatment of cutaneous T-cell lymphoma. A treatment technique has been developed at our center, using the Philips SL 75/10 linear accelerator. In our method, the patient is irradiated in a recumbent position by five pairs of uncollimated electron beams at a source to skin distance of 150 cm. This method provides a practical solution to clinical requirements with respect to uniformity of electron dose and low X-ray contamination. Its implementation does not require special equipment or modification of the linear accelerator, 19 of 23 patients (83%) with mycosis fungoides, treated by this method, achieved complete regression of their cutaneous lesions.[Abstract] [Full Text] [Related] [New Search]