These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An automated, high-throughput, 384 well Cytochrome P450 cocktail IC50 assay using a rapid resolution LC-MS/MS end-point.
    Author: Youdim KA, Lyons R, Payne L, Jones BC, Saunders K.
    Journal: J Pharm Biomed Anal; 2008 Sep 10; 48(1):92-9. PubMed ID: 18584988.
    Abstract:
    The current study focused on the development of an automated IC50 cocktail assay in a miniaturized 384 well assay format. This was developed in combination with a significantly shorter high pressure liquid chromatography (HPLC) separation and liquid chromatography-mass spectrometry (LC-MS/MS) run-time; than those currently reported in the literature. The 384-well assay used human liver microsomes in conjunction with a cocktail of probe substrates metabolized by the five major CYPs (tacrine for CYP1A2, diclofenac for CYP2C9, (S)-mephenytoin for CYP2C19, dextromethorphan for CYP2D6 and midazolam for CYP3A4). To validate the usefulness of the automated and analytical methodologies, IC50 determinations were performed for a series of test compounds known to exhibit inhibition across these five major P450s. Eight compounds (sertraline, disulfuram, ticlopidine fluconazole, fluvoxamine, ketoconazole, miconazole, paroxetine, flunitrazepam) were studied as part of a cocktail assay, and against each CYPs individually. The data showed that the IC50s generated with cocktail incubations did not differ to a great extent from those obtained in the single probe experiments and hence unlikely to significantly influence the predicted clinical DDI risk. In addition the present method offered a significant advantage over some of the existing cocktail analytical methodology in that separation can be achieved with run times as short as 1 min without compromising data integrity. Although numerous studies have been reported to measure CYP inhibition in a cocktail format the need to support growing discovery libraries not only relies on higher throughput assays but quicker analytical run times. The current study reports a miniaturized high-throughput cocktail IC50 assay, in conjunction with a robust, rapid resolution LC-MS/MS end-point offered increased sample throughput without compromising analytical sensitivity or analyte resolution.
    [Abstract] [Full Text] [Related] [New Search]