These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The Powerlink system for endovascular abdominal aortic aneurysm repair: six-year results.
    Author: Wang GJ, Carpenter JP, Endologix Investigators.
    Journal: J Vasc Surg; 2008 Sep; 48(3):535-45. PubMed ID: 18635335.
    Abstract:
    OBJECTIVE: We compared the results of endovascular repair using the Powerlink endovascular graft with conventional open abdominal aortic aneurysm repair through a 6-year follow-up period. METHODS: Two hundred fifty-eight patients with abdominal aortic aneurysms were prospectively enrolled in a multicenter trial and underwent endovascular repair (N = 192) or conventional open surgery (N = 66). All endovascular repairs were approached through a surgically exposed femoral artery and a percutaneously accessed femoral artery. Study endpoints included all-cause mortality and morbidity. Follow-up imaging consisted of contrast-enhanced CT scans and plain abdominal x-rays at 1, 6, 12 months, and annually postoperatively. RESULTS: Technical success was achieved in 97.9% of test patients, with four failed insertions (three early conversions because of deployment issues, one access failure). Mean follow-up was 4.1 +/- 1.7 years (test group) and 3.1 +/- 1.9 years (control group). Perioperative morbidity and mortality were significantly reduced in the test group compared with the control group (P < .05). At 6 years, all-cause mortality and morbidity was no different in the Powerlink group compared with the open repair group. There were no reported stent fractures, graft disruptions, or aneurysm ruptures. Core laboratory-reported endoleaks included proximal or distal type I (n = 1) and type I/II (n = 3), with no type III or type IV endoleaks. One explant (0.5%) was undertaken to resolve a refractory type I endoleak. A total of 37 secondary procedures were performed in 26 patients to treat site-reported endoleak (n = 26; 7 for type I and 19 for type II), graft limb occlusion (n = 7), native artery occlusion (n = 3), or endograft migration (n = 1). A reduction in mean aneurysm sac diameters and volumes has been noted at every follow-up interval. CONCLUSION: Consistent with other reports, perioperative morbidity and mortality were significantly reduced in the endovascular group compared with the open repair group. Six-year follow-up of patients treated with the Powerlink system demonstrates the continued safety and efficacy of its treatment of abdominal aortic aneurysm.
    [Abstract] [Full Text] [Related] [New Search]