These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of brazilein in rat plasma after intravenous administration by HPLC.
    Author: Lan J, Hu J, Li B, Xing D, Liu C, Wang W, Du L.
    Journal: Biomed Chromatogr; 2008 Nov; 22(11):1201-5. PubMed ID: 18651610.
    Abstract:
    Quantification of brazilein in rat plasma following intravenous administration was achieved by reversed-phase high-performance liquid chromatography using a mobile phase of acetonitrile-0.05 m potassium dihydrogen phosphate water (containing 0.5% triethylamine, pH 3.0; 20:80 v/v) and UV detection at 445 nm. The method was linear (determination coefficient, r(2) = 0.9992) within the tested range (0.313-5.0 microg/mL). Intra- and inter-day precision coefficients of variation and accuracy bias were acceptable (maximal CV value was 2.06% for intra-day and 1.71% for inter-day) over the entire range. The recoveries were 81.48, 84.61 and 82.83% for concentrations of 0.313, 1.25 and 5.0 microg/mL, respectively. The concentration-time curve of brazilein after intravenous administration was fitted to the two-compartment model. This is the first time that brazilein in rat plasma was detected by HPLC-UV method and its pharmacokinetic characteristic was comprehensively studied.
    [Abstract] [Full Text] [Related] [New Search]