These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Detection of tethered biocide moiety segregation to silicone surface using sum frequency generation vibrational spectroscopy.
    Author: Ye S, McClelland A, Majumdar P, Stafslien SJ, Daniels J, Chisholm B, Chen Z.
    Journal: Langmuir; 2008 Sep 02; 24(17):9686-94. PubMed ID: 18666787.
    Abstract:
    Polymer surface properties are controlled by the molecular surface structures. Sum frequency generation (SFG) vibrational spectroscopy has been demonstrated to be a powerful technique to study polymer surface structures at the molecular level in different chemical environments. In this research, SFG has been used to study the surface segregation of biocide moieties derived from triclosan (TCS) and tetradecyldimethyl (3-trimethoxysilylpropyl) ammonium chloride (C-14 QAS) that have been covalently bound to a poly(dimethylsiloxane) (PDMS) matrix. PDMS materials are being developed as coatings to control biofouling. This SFG study indicated that TCS-moieties segregate to the surface when the bulk concentration of TCS-moieties exceeds 8.75% by weight. Surface segregation of C-14 QAS moieties was detected after 5% by weight incorporation into a PDMS matrix. SFG results were found to correlate well with antifouling activity, providing a molecular interpretation of such results. This research showed that SFG can aid in the development of coatings for controlling biofouling by elucidating the chemical structure of the coating surface.
    [Abstract] [Full Text] [Related] [New Search]