These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Point-of-use water filtration reduces endemic Pseudomonas aeruginosa infections on a surgical intensive care unit. Author: Trautmann M, Halder S, Hoegel J, Royer H, Haller M. Journal: Am J Infect Control; 2008 Aug; 36(6):421-9. PubMed ID: 18675148. Abstract: BACKGROUND: Endemic infections because of Pseudomonas aeruginosa were observed on a surgical intensive care unit (ICU) for a period of >24 months. Tap water probing revealed persistent colonization of all ICU water taps with a single P aeruginosa clonotype. METHODS: Water outlets of the ICU were equipped with disposable point-of-use water filters, changed in weekly and, later, 2-week intervals. To delineate the effect of the filters, 4 study approaches were followed: (1) a descriptive analysis of the incidence of P aeruginosa colonizations and infections, (2) microbiologic examinations of tap water before and after installation of the filters, (3) a comparative cohort analysis of representative patient samples from the prefilter and postfilter time periods, and (4) an analysis of general ward variables for the 2 periods. RESULTS: (1) The mean monthly rate (+/-SD) of P aeruginosa infection/colonization episodes was 3.9 +/- 2.4 in the prefilter and 0.8 +/- 0.8 in the postfilter period. P aeruginosa colonizations were reduced by 85% (P < .0001) and invasive infections by 56% (P < .0003) in the postfilter period. (2) Microbiologic examinations of tap water revealed growth of P aeruginosa in 113 of 117 (97%) samples collected during the prefilter period, compared with 0 of 52 samples taken from filter-equipped taps. (3) In the comparative cohort analysis, a number of patient-related variables were significantly associated with P aeruginosa colonization/infection. Considering these variables in a multivariate analysis, belonging to the postfilter cohort was the factor most strongly associated with a reduced risk of P aeruginosa positivity (relative risk, 0.04; P = .0002). (4) General ward variables such as bed occupancy, personnel-to-patient ratio, or microbiologic culturing density did not differ significantly between the 2 periods. CONCLUSION: Taking into account various patient-related and general ward variables, point-of-use water filtration was associated with a significant reduction of chronically endemic P aeruginosa colonizations/infections on a surgical ICU.[Abstract] [Full Text] [Related] [New Search]