These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Cardiac output following fetoscopic coagulation of major placental vessels in fetal sheep. Author: Tchirikov M, Strohner M, Popovic S, Hecher K, Schröder HJ. Journal: Ultrasound Obstet Gynecol; 2008 Dec; 32(7):917-22. PubMed ID: 18677701. Abstract: OBJECTIVES: To measure changes in cardiac output (CO) after partial cord occlusion in fetal sheep in order to investigate pathophysiological fetal adaptation mechanisms in a simulated acute placental insufficiency model under standardized conditions, with the aim of finding relevant methods for monitoring human fetuses during stress situations. METHODS: We used minimally invasive, percutaneous endoscopic techniques to close umbilical vessels in mid-gestational fetal sheep. Placental blood flow was reduced by preferentially closing first arterial and then the concomitant venous umbilical vessels within a short time interval. The investigations were carried out on 11 pregnant ewes at a median gestational age of 86 (range, 73-95) days. Major placental arteries and veins were occluded permanently by coagulation with bipolar forceps under percutaneous fetoscopic control. The fetal CO and Doppler parameters in the ductus venosus (DV), umbilical artery (UA) and umbilical vein (UV) were measured. RESULTS: In spite of heart rate reduction, the CO was not significantly affected by vessel occlusion (mean +/- SD, 500 +/- 194 mL/min before and 457 +/- 219 mL/min after coagulation) because stroke volume slightly increased from 2.65 +/- 1.16 mL/beat to 3.1 +/- 1.5 mL/beat. The right to left CO ratio remained at 1.4. The UV flow/combined CO ratio decreased from 34 +/- 14% to 25 +/- 10% after vessel coagulation. The pulsatility index in the DV increased from 0.4 +/- 0.1 to 0.7 +/- 0.4. The DV blood flow volume remained relatively constant after the intervention. The DV shunting rate, given as DV/UV flow ratio, increased significantly from 30.8 +/- 4.7% to 59.3 +/- 25.0%. CONCLUSIONS: The nearly simultaneous closure of arterial and venous umbilical vessels changed the flow pattern in the UA and significantly reduced placental blood perfusion. It did not distinctly change the blood flow volume rate through the DV, and consequently the DV shunting rate was increased. The combined CO was not significantly affected by the vascular obstruction, whereas the fraction of combined CO directed to the placenta was reduced.[Abstract] [Full Text] [Related] [New Search]