These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Supercritical fluid extraction as an on-line clean-up technique for rapid amperometric screening and alternative liquid chromatography for confirmation of paraquat and diquat in olive oil samples.
    Author: Zougagh M, Bouabdallah M, Salghi R, Hormatallah A, Rios A.
    Journal: J Chromatogr A; 2008 Sep 12; 1204(1):56-61. PubMed ID: 18703198.
    Abstract:
    A rapid and simple method for the direct screening of paraquat (PQ) and diquat (DQ) in olive oil samples is proposed. The sample screening method involves supercritical fluid extraction (SFE) (clean-up followed by the extraction of the analytes) followed by continuous flow electrochemical detection. Those samples for which the total concentration is close to or above the threshold limit established by the Columbian Society for Social Protection (0.05 microg g(-1)) are subsequently analyzed by liquid chromatography (LC) with diode array detection (DAD). This confirmation method allows the determination of PQ and DQ in the range between 0.04 and 1.0 microg g(-1), with average relative standard deviations lower than 3.5%, and 0.003 and 0.002 microg g(-1) detection limits for PQ and DQ, respectively. The proposed arrangement opens up interesting prospects for the direct determination of polar pesticides in complex samples with a good throughput and a high level of automation.
    [Abstract] [Full Text] [Related] [New Search]