These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Contrast-enhanced 18F-FDG PET/CT: 1-stop-shop imaging for assessing the resectability of pancreatic cancer.
    Author: Strobel K, Heinrich S, Bhure U, Soyka J, Veit-Haibach P, Pestalozzi BC, Clavien PA, Hany TF.
    Journal: J Nucl Med; 2008 Sep; 49(9):1408-13. PubMed ID: 18703604.
    Abstract:
    UNLABELLED: Patients with pancreatic cancer continue to have a poor prognosis, with a 5-y survival rate of less than 5%. Surgery is the only treatment that offers a potential cure. Determining resectability is the principal goal of staging in pancreatic cancer patients. Our objective was to evaluate the value of combined contrast-enhanced (18)F-FDG PET/CT in assessing the resectability of pancreatic cancer and to compare enhanced PET/CT with the performance of PET alone and unenhanced PET/CT. METHODS: Fifty patients (25 women and 25 men; mean age, 64.3 y; range, 39-84 y) with biopsy-proven pancreatic adenocarcinoma underwent enhanced (18)F-FDG PET/CT for the evaluation of resectability. Criteria for unresectability were distant metastases, peritoneal carcinomatosis, arterial infiltration, or invasion of neighboring organs other than the duodenum. The performance of enhanced PET/CT regarding resectability was compared with that of PET alone and unenhanced PET/CT. Histology, intraoperative findings, and follow-up CT with clinical investigations were used as the reference standard. RESULTS: According to the reference standard, 27 patients had disease that was not resectable because of distant metastases (n=17), peritoneal carcinomatosis (n=5), or local infiltration (n=5). In the assessment of resectability, PET alone had a sensitivity of 100%, specificity of 44%, accuracy of 70%, positive predictive value of 61%, and negative predictive value of 100%; unenhanced PET/CT had respective values of 100%, 56%, 76%, 66%, and 100%; and enhanced PET/CT, 96%, 82%, 88%, 82%, and 96%. In 5 patients, unresectability was missed by all imaging methods and was diagnosed intraoperatively. Enhanced PET/CT was significantly superior to PET alone (P=0.035), and there was a trend for enhanced PET/CT to be superior to unenhanced PET/CT (P=0.070). CONCLUSION: The use of enhanced PET/CT as a 1-stop-shop imaging protocol for assessing the resectability of pancreatic cancer is feasible and accurate. Enhanced PET/CT is significantly superior to PET alone.
    [Abstract] [Full Text] [Related] [New Search]