Search MEDLINE/PubMed
Title: Area ratio effects on metal ion release from amalgam in contact with gold. Author: Johansson C, Moberg LE. Journal: Scand J Dent Res; 1991 Jun; 99(3):246-53. PubMed ID: 1871535. Abstract: The effect of area ratio, chloride concentration and brushing on amalgam in contact with gold was studied by measuring the amounts of elements released in the electrolyte. A type III gold alloy was stored for 4 months in contact with a conventional amalgam, area relations 6/1 and 6/3, in an electrolyte containing 85 mM NaCl with 10 mM phosphate buffer. A specimen with area relation 6/1 was also stored in a 10 mM NaCl solution with 10 mM phosphate buffer. The solutions were renewed each month and analyzed for Cu, Zn, Sn, Hg, and Ag in an atomic absorption spectrophotometer. Cross-sections of the amalgams were studied in a scanning electron microscope. The tendency for Sn and Cu to be released from the amalgam was greater than for the other elements. The Sn-release probably mainly originated from surface corrosion and Cu-release from subsurface corrosion. A stronger galvanic influence enhanced only the release of Cu, and to a less extent Zn. The subsurface corrosion of the amalgam and increasing release of Cu was, in contrast to the other elements, largely dependent on a high chloride concentration in the electrolyte. Light brushing of the specimens had no effect on the amounts of elements released.[Abstract] [Full Text] [Related] [New Search]